This pressure transmitter acquires the relative and absolute pressure. The measuring system is fully welded and can be used for all media. The silicon sensor is resistant to overloading even in the lowest measuring ranges. It is mainly used in mechanical and plant engineering and is also suitable for hydrogen applications in electrolyzers, synthesis plants, and mobile fuel cells.
general technical data | |
---|---|
Output | 4 to 20 mA two-wire; DC 0 to 10 V three-wire |
Process connection | All screw connections that are standard in the industry |
Accuracy (linearity) | 0.2 to 0.3 % |
Medium temperature | -40 to +125 °C |
Input | 0 to 100 bar relative pressure; 0 to 40 bar absolute pressure |
Measuring system | Silicon sensor with stainless steel separating membrane |